Model |
Singlemode OFTM-5730
|
Multimode OFTM-5610B
|
|
Output/input connector |
SC/UPC removeable/cleanable |
SC/UPC removable/cleanable |
|
Wavelengths |
1310 ± 25 nm and 1550 ± 30 nm |
850 ± 20 nm and 1300 ± 25 nm |
|
Fiber types tested |
9/125 µm singlemode |
50/125 µm or 62.5/125 µm multimode |
|
Event deadzone |
1310/1550 nm: 1 m typical |
850 nm: 0.5 m typical
1300 nm: 1.3 m typical |
|
Attenuation deadzone |
1310/1550 nm: 8 m typical |
850 nm: 4.5 m typical
1300 nm: 10.5 m typical |
|
Pulse width |
1310 nm/1550 nm: 5 ns, 20 ns, 40 ns, 100 ns, 300 ns, 1 µs, 3 µs, 10 µs |
850 nm: 4 ns, 20 ns
1300 nm: 8 ns, 40 ns, 100 ns, 200 ns,
400 ns, 650 ns |
|
Max distance range |
1310/1550 nm: 60 km |
850 nm: 3 km, 1300 nm: 7 km |
|
Dynamic range |
1310 nm: 26 dB typical
1550 nm: 24 dB typical |
850 nm: 15 dB typical
1300 nm: 14 dB typical |
|
Testing speed |
Auto OTDR 15 seconds typical
Manual OTDR 15 seconds to 3 min |
<10s for two wavelengths at 2 km with 25 cm resolution
<30s for two wavelengths at 400 m with 3 cm resolution |
|
Output power |
1310 nm: >28 mW-pk
1550 nm: >24 mW-pk |
850 nm: >110 mW-pk
1300 nm: >22 mW-pk |
|
Loss threshold |
.01 dB to 1.5 dB inclusive |
.2 dB |
|
Linearity |
|
Sample resolution |
3 cm to 400 cm |
3 cm to 50 cm |
|
Reflectance accuracy |
|
ORL accuracy |
|
Distance accuracy |
± 1 m ± 0.005% of distance ± 50% of resolution ± IOR error ± event location error |
Laser classification |
Class 1 CDRH, complies to EN 60825-2 |
Battery |
Li-Ion |
Battery life |
8 hours typical |
Connections |
USB, RS-232, FiberInspectorTM camera port, PS-2 keyboard |
Memory card |
SD MMC |
Dimensions |
11.4 x 7.5 x 2.5 in (29.0 x 19.1 x 6.4 cm) |
Weight |
4.5 lbs (1.9 kg) Main with module and battery |